Turnkey Cleanroom Projects
Six stages. One accountable partner.
Click a stage to see what our team delivers.
Stage 1 of 6
Design
- URS review, layout and zoning
- Pressure cascade, airflow and HVAC design
- Material and personnel flow per GMP
- Design qualification (DQ)
Stage 2 of 6
Manufacturing
- Panels, doors and pass boxes made in Vadodara
- LAF, BSC and furniture fabricated in-house
- Factory checks before dispatch
- Export-grade flat-pack packing
Stage 3 of 6
Installation
- Experienced site teams and supervisors
- Clean-construction protocols
- Coordinated civil, HVAC and electrical interfaces
- Snag-free handover
Stage 4 of 6
Commissioning
- AHU and airflow balancing
- Pressure cascade set-up
- Interlock, alarm and control checks
- Operator training
Stage 5 of 6
Validation
- HEPA integrity (PAO) testing
- Particle counts and recovery tests
- Smoke studies (airflow visualisation)
- IQ / OQ / PQ execution
Stage 6 of 6
Documentation
- Complete qualification reports
- As-built drawings and manuals
- Calibration certificates
- Audit support
Validation & Qualification
Independent testing with audit-ready reports
Our validation engineers qualify new and existing cleanrooms, clean-air equipment and HVAC systems to ISO 14644-3 methods and your own SOPs.


AMC & Facility Upgrades
Keep your facility audit-ready, year after year
Regulations tighten and facilities age. Our annual maintenance contracts and upgrade services keep your rooms performing as validated.
- Planned preventive maintenance and periodic requalification
- HEPA and pre-filter replacement with integrity testing
- Priority breakdown response for production-critical areas
- Gap assessments for revised Schedule M, EU GMP Annex 1 and USFDA inspections
- Upgrades of finishes, doors, pass boxes and pressure cascades without long shutdowns
Engineering Tool
ISO 14644-1 cleanroom class explorer
Select a class to see its particle limits, the matching EU GMP grade and typical applications, then estimate the airflow for your room.
| Particle size | 0.1 µm | 0.2 µm | 0.3 µm | 0.5 µm | 1 µm | 5 µm |
|---|---|---|---|---|---|---|
| Limit |
Limits from ISO 14644-1:2015, Table 1. A dash means the size is not specified for that class.
Airflow estimator
Industry rule-of-thumb ranges for an early budget discussion. Final design depends on heat load, process and occupancy.
Get an engineered design for this room