sales@labservicesindia.com +91 98250 72978 Mon–Sat 9:30–18:30 IST
Designed to ISO 14644 & EU GMP Brochure
Lab ServicesThe Clean Room PeopleSince 1997

Services

Turnkey cleanroom projects, validation and lifetime support.

Turnkey Cleanroom Projects

Six stages. One accountable partner.

Click a stage to see what our team delivers.

Design stage

Stage 1 of 6

Design

  • URS review, layout and zoning
  • Pressure cascade, airflow and HVAC design
  • Material and personnel flow per GMP
  • Design qualification (DQ)

Validation & Qualification

Independent testing with audit-ready reports

Our validation engineers qualify new and existing cleanrooms, clean-air equipment and HVAC systems to ISO 14644-3 methods and your own SOPs.

HEPA filter integrityPAO / DOP aerosol challenge and scan testing
Particle countsNon-viable classification to ISO 14644-1
Airflow & air changesVelocity, volume and ACPH measurement
Pressure cascadeDifferential pressure and containment checks
Recovery testsClean-up time after particle challenge
Smoke studies & IQ/OQ/PQAirflow visualisation, protocols and reports
Air handling unit commissioned and validated by Lab Services
Modular cleanroom panels with flush view window maintained under AMC

AMC & Facility Upgrades

Keep your facility audit-ready, year after year

Regulations tighten and facilities age. Our annual maintenance contracts and upgrade services keep your rooms performing as validated.

  • Planned preventive maintenance and periodic requalification
  • HEPA and pre-filter replacement with integrity testing
  • Priority breakdown response for production-critical areas
  • Gap assessments for revised Schedule M, EU GMP Annex 1 and USFDA inspections
  • Upgrades of finishes, doors, pass boxes and pressure cascades without long shutdowns
Discuss an AMC

Engineering Tool

ISO 14644-1 cleanroom class explorer

Select a class to see its particle limits, the matching EU GMP grade and typical applications, then estimate the airflow for your room.

ISO 7

Maximum particles per m³ of air, equal to or larger than the size shown
Particle size0.1 µm0.2 µm0.3 µm0.5 µm1 µm5 µm
Limit

Limits from ISO 14644-1:2015, Table 1. A dash means the size is not specified for that class.

Airflow estimator

Room volume–
Air changes / hour–
Supply airflow–
HEPA filters (approx.)–

Industry rule-of-thumb ranges for an early budget discussion. Final design depends on heat load, process and occupancy.

Get an engineered design for this room

Planning a new facility or an upgrade?

Share your layout or URS and our engineers will come back with a concept and budget within 2–3 working days.

Chat with us

Key features